Functionality in the PROFIBUS DPV2 device

77

G1_XIST1 Preset control = disabled
With the parameter G1_XIST 1 preset control disabled, and if the

position value increases or decreases outside the maximum value

or below 0, the device will output the maximum position value

within the scaled total range for the position value G1_XIST 2. The

position value G1_XIST 1 is not limited to the scaled total range.

For the position value G1_XIST 1, the device will continue to

output a position value within the encoder’s total measuring range

(up to 33554432 positions for a 25 bit encoder)

Example of non-cyclic scaling G1_XIST 1 Preset control
disabled:
Measuring units per revolution = 100

Total measuring range = 5000

(number of revolutions 50)

Figure 24

Non-cyclic scaling G1_XIST 1 Preset control disabled