Functionality in the PROFIBUS DPV2 device

67

8.1 Code sequence

The code sequence defines whether the absolute position value

should increase during clockwise or counter clockwise rotation of

the encoder shaft seen from flange side. The code sequence is by

default set to increase the absolute position value when the shaft

is turned clockwise (0).

Attribute

Meaning

Value

CW

Increasing position values with clockwise

rotation (seen from shaft side)

0

CCW

Increasing position values with counter

clockwise rotation (seen from shaft side)

1

Table 31

Code sequence attributes

Note: The position value will be affected when the code

sequence is changed during operation. It might be
necessary to perform a preset after the code sequence
has been changed.


Note Code sequence for the linear scale is not supported by

the gateway.


8.2 Class 4 functionality

This parameter enables or disables the measuring task functions

Scaling, Preset and Code sequence. If the function is enabled,

scaling and Code sequence control affects the position value in

G1_XIST1, G1_XIST2 and G1_XIST3. A preset will in this case

always affect G1_XIST2 and G1_XIST3 but if the parameter

G1_XIST1 Preset control is disabled the preset will not affect the

position value in G1_XIST1.

Attribute

Meaning

Value

Enable

Scaling/Preset/ code sequence control

enabled

1

Disable

Scaling/Preset/ code sequence control

disabled

0

Table 32

Class 4 functionality attributes