Absolute encoder installation

26

3.3 Shielding philosophy

To achieve the highest possible noise immunity and resistance

against other EMI related disturbances the bus and power supply

cables shall always be shielded. The screen should be connected

to ground on both ends of the cable. In certain cases

compensation current might flow over the screen. Therefore a

potential compensation wire is recommended.

3.4 GSD file

In order to start using an absolute encoder with PROFIBUS DP

interface, a device description file needs to be downloaded and

imported to the configuration software.

The device description file is called a Generic Station Description

file and contains the necessary implementation parameters

needed for a PROFIBUS DP device.

Available GSD files can be downloaded from

www.heidenhain.com.

GSD file

Gateway functionality

GSD file

Absolute encoder PROFIBUS DPV2

Enc_0aaa

Table 9

Available GSD file for DPV2 encoder

The GSD data is saved in the PROFIBUS master and transferred

once to the encoder when the system is powered on. If the

encoder has been started with one GSD file and a new GSD file

with a different ID-number shall be used, the encoder needs to be

restarted before it can use the new GSD file.