7.4 Detailed description of supported parameters
7.4.1 Parameter 918, read only
918 unsigned int, presents the node address of the device.
7.4.2 Parameter 922, read only
922 unsigned int, presents which telegram is used. Telegram
81, 82, 83 or 84 is possible.
7.4.3 Parameter 925, read/write
925 unsigned int, maximum allowed MLS (Master sign-of-life)
error. Parameter 925 may be used to set a maximum on how
many consecutive Sign-of-life failures may occur.
7.4.4 Parameter 964, read only
964 unsigned int, Device indentification
964[0] = Manufacturer Id. This is set during manufacturing of the
encoder.
964[1] = 0 DU Drive unit type, always set to 0.
964[2] = 201 Software version
964[3] = 2009 Software year
964[4] = 2805 Software day and month
964[5] = 1 Number of drive objects (D
7.4.5 Parameter 965, read only
965 OctetString 2, Encoder profile number
965[0] =0x3D Encoder profile number
965[1] = 31 or 41 Encoder profile version, set by customer
(user_parameters)
7.4.6 Parameter 971, read/write
971 unsigned int, Store the local parameter set to a non volatile
memory. Preset value is saved when writing value 1 and is set to
0 by the encoder firmware when finished. This means that the
preset value has been saved when reading back value 0.
7.4.7 Parameter 974, read only
974 unsigned int
974[0] = 96 Max array length supported by parameter channel.
974[1] = 1 Numbers of multi parameters, 1 = no support of
multi parameters.
974[2] = 1000 max time to process parameter request,
n x 10 ms.