beautypg.com

Rs-422/v.11 interface, Ethernet interface rj45 socket – HEIDENHAIN iTNC 530 (340 49x-05) User Manual

Page 637

background image

HEIDENHAIN iTNC 530

637

1

8

.2 Pin La

y

outs and Connecting Cables f

o

r the D

a

ta Int

e

rf

aces

RS-422/V.11 interface

Only non-HEIDENHAIN devices are connected to the RS-422
interface.

Ethernet interface RJ45 socket

Maximum cable length:

„

Unshielded: 100 m

„

Shielded: 400 m

The interface complies with the requirements of
EN 50 178 for “low voltage electrical separation.”

The pin layouts on the TNC logic unit (X28) and on the
adapter block are identical.

TNC

Connecting cable 355 484-xx

Adapter block
363 987-01

Female

Assignment

Male

Color

Female

Male

Female

1

RTS

1

Red

1

1

1

2

DTR

2

Yellow

2

2

2

3

RXD

3

White

3

3

3

4

TXD

4

Brown

4

4

4

5

Signal GND

5

Black

5

5

5

6

CTS

6

Violet

6

6

6

7

DSR

7

Grey

7

7

7

8

RXD

8

White/Green

8

8

8

9

TXD

9

Green

9

9

9

Housing

Ext. shield

Housing

Ext. shield

Housing

Housing

Housing

Pin

Signal

Description

1

TX+

Transmit Data

2

TX–

Transmit Data

3

REC+

Receive Data

4

Vacant

5

Vacant

6

REC–

Receive Data

7

Vacant

8

Vacant