Special Cycles

DWELL TIME (Cycle 9)

This causes the execution of the next block within a running program to
be delayed by the programmed dwell time.

8

CYCL DEF: Select Cycle 9 DWELL TIME

8

Enter the dwell time in seconds

PGM CALL (Cycle 12)

8

CYCL DEF: Select Cycle 12 PGM CALL

8

Enter the name of the program to be called

48 CYCL DEF 9.0 DWELL TIME

49 CYCL DEF 9.1 DWELL 0.5

Cycle 12 PGM CALL must be called to become active.

7 CYCL DEF 12.0 PGM CALL

8 CYCL DEF 12.1 LOT31

9 L X+37.5 Y-12 R0 FMAX M99

0 BEGIN PGM
LOT31 MM

7 CYCL DEF 12.0
PGM CALL

8 CYCL DEF 12.1
LOT31

9 ... M99

END PGM LOT31