Datum setting (cycle 247) – HEIDENHAIN iTNC 530 (340 49x-03) Pilot User Manual
Page 91

91
Coo
rdin
a
te
Transfor
mat
ion
Cycles
DATUM SETTING (Cycle 247)
8
CYCL DEF: Select Cycle 247 DATUM SETTING
8
Number for datum: Q339. Enter the number of the new datum from
the preset table.
13 CYCL DEF 247 DATUM SETTING
Q339=4
;DATUM NUMBER
When activating a datum from the preset table, the TNC
resets all coordinate transformations that were activated
with the following cycles:
Cycle 7, Datum Shift
Cycle 8, Mirroring
Cycle 10, Rotation
Cycle 11, Scaling
Cycle 26, Axis-Specific Scaling
However, the coordinate transformation from Cycle 19,
Tilted Working Plane, remains active.
If you activate preset number 0 (line 0), then you activate the
datum that you last set by hand in a manual operating mode.
Cycle 247 is not functional in Test Run mode.
Z
Z
X
X
Y
Y