Coo
rdin
a
te
Transfor
mat
ion
Cycles
SCALING FACTOR (Cycle 11)
8
CYCL DEF: Zyklus 11 MASSFAKTOR wählen
8
Enter the scaling factor (SCL):
Input range: 0.000 001 to 99.999 999
Reduction... SCL<1
Enlargement... SCL>1
To cancel the scaling: Re-enter the cycle definition with SCL1.
11 CALL LBL1
12 CYCL DEF 7.0 NULLPUNKT
13 CYCL DEF 7.1 X+60
14 CYCL DEF 7.2 Y+40
15 CYCL DEF 11.0 MASSFAKTOR
16 CYCL DEF 11.1 SCL 0.75
17 CALL LBL1
SCALING FACTOR can be effective in the working plane only
or in all three main axes (depending on MP7410).