24

Path functions

Inserting a Chamfer CHF between Two
Straight Lines

8

Chamfer side length

8

Feed rate F

7 L X+0 Y+30 RL F300 M3

8 L X+40 IY+5

9 CHF 12 F250

10 L IX+5 Y+0

„

You cannot start a contour with a CHF block.

„

The radius compensation before and after the CHAMFER
block must be the same.

„

An inside chamfer must be large enough to accommodate
the called tool.

X

Y