3.5.9 Post-Process Measuring Status
Display
Selection: Menu item ”Display – PPM Status”
(automatic mode)
The ”PPM Info” dialog box contains information on
the status of the measured values and displays the
transferred results:
■
”Measured-value coupling” (control parameter 10)
■
Off: Measuring results are immediately
transferred. Previous values are overwritten.
■
On: Measuring results are not transferred until
the previous results have been processed.
■
Measured values valid: Status of the measured
values (after the measured values have been
transferred with G915, the status ”No” is
displayed).
■
#939: Total result of last measurement.
■
#940..956: Measuring results last transferred by the
measuring function.
If you select ”Init,” the post-process measuring
function is re-initialized and all measured values are
deleted.
3.5 A
u
tomatic Mode of Oper
ation
The post-process measuring function stores the measured
values received in the clipboard. The ”PPM Info” dialog box
displays in #939..956 the values contained in the clipboard -