51

3.5.9 Post-Process Measuring Status

Display

Selection: Menu item ”Display – PPM Status”
(automatic mode)

The ”PPM Info” dialog box contains information on
the status of the measured values and displays the
transferred results:

”Measured-value coupling” (control parameter 10)

Off: Measuring results are immediately

transferred. Previous values are overwritten.

On: Measuring results are not transferred until

the previous results have been processed.

Measured values valid: Status of the measured

values (after the measured values have been
transferred with G915, the status ”No” is
displayed).

#939: Total result of last measurement.

#940..956: Measuring results last transferred by the

measuring function.

If you select ”Init,” the post-process measuring
function is re-initialized and all measured values are
deleted.

3.5 A

u

tomatic Mode of Oper

ation

The post-process measuring function stores the measured
values received in the clipboard. The ”PPM Info” dialog box
displays in #939..956 the values contained in the clipboard -
not the variables.