5. Connection and Statup

5 - 30

Planning and Installation - Rev. 3 / 04.2005

5.5.1.2 AC Power, Grounding

PE

TE

AC POWER IN

1

2

1

2

Item

No.:

Socket / Connector

Description

Socket type

Connector type

Function

1

AC POWER IN 1 + 2

IEC-320, CEE-22

Convenience outlet for power supply to the

mainframe.

Socket 1:

Redundant power supply

Socket 2:

Standard power supply

In order to prevent power disturbances, with

option redundant power supply the mains

cords should be connected to separate elec-

tricity supply.

Caution

Double-pole or neutral fusing.

After operation of the protective device, parts of

the equipment that remain under voltage might

represent a hazard during servicing.

2

TE / PE

M4 threaded pins

Terminal screws for unit earthing

PE protective earth

TE technical earth

When leaving the factory, both terminal screws

are shorted with a jumper.

Detailed information see in section “Grounding

Requirements”