5 monitor tally operation – Grass Valley XtenDD DD User Manual

Page 127

background image

6. Tally Signalling

6 - 9

Planning and Installation - Rev. 3 / 04.2005

6.5

MONITOR TALLY OPERATION

6.5.1

MONITOR TALLY MAIN / M/E1-3 / CLEAN

The monitoring tally outputs ‘MonTallyMain’, ‘MonTallyM/E1..3’ and ‘MonTally-

Clean’ are returning the tally state of the corresponding stage.

Example:

The M/E2 has got OnAir at ‘Tally In M/E2’. Thus M/E2 is on Air and returns ‘OnAir

at MonTally M/E2’. As M/E2 sources the video of M/E1, the M/E1 is OnAir too. As

a result, this M/E returns OnAir at its ‘MonTally M/E2’.

MonTally M/E2

OnAir

Tally In M/E2

M/E1

(on air as sourced by M/E2)

MonTally M/E2

OnAir

Tally In M/E2

OnAir

M/E 2

(OnAir caused by tally M/E2)

sources

6.5.2

MONITOR TALLY AUX1-15

The monitoring tally outputs ‘MonTallyAux1...15’ are returning the tally state of the

stage that is sourced by the aux bus.

Example:

The M/E2 has got OnAir at ‘Tally In M/E2’. Thus M/E2 is on Air and returns ‘OnAir

at MonTally M/E2’. As M/E2 sources the video ‘Input7’, the ‘Input7’ is OnAir too. As

AUX4 sources Input7 too, the AUX4 returns OnAir at its ‘MonTally AUX4’.

MonTally M/E2

OnAir

Tally In M/E2

OnAir

M/E2

(on air by Tally In M/E2)

MonTally AUX4

OnAir

Tally In

AUX4

AUX4

Input7

(on air as sourced by M/E2)

sources

sources