5. Connection and Startup

5 - 55

Planning and Installation - Rev. 3 / 04.2005

5.8

LAN SPECIFICATION

For operation of the XtenDD switcher, multiple mainframes and panels designed

for different applications can be connected and operated via a Local Area Network

LAN.

Caution:

The XtenDD switchers are real-time devices. Other devices con-

nected to the same LAN cabling will cause degradation in com-

munications and reduce the reliability of the Switcher.

Caution:

For the system to operate, the LAN cable MUST be 50 ohms and

the cable MUST be terminated with a 50 ohm termination on

EACH end.

The applied LAN (Cheapernet) connection features the following characteristics:

max 150 m

max

min 0,5 m

Mainframe

Repeater

Cheapernet

LAN

Panel

Controller

Panel

PC

Other

Devices

150 m

BNC T-Type

50-Ohms Terminator

Connector

to LAN cable

to Equipment connector

50
W

50
W

Repeater

D

Cheapernet connection cable Kv 770 (50-ohms coax)

D

Maximum length per segment = 150 m,

D

Minimum length per segment = 0.5 m

D

Longer distances are possible with a repeater, i.e. each repeater provides a fur-
ther segment with an extension of up to 150 m

D

10 units per segment at maximum.

D

End units must be terminated with a 50-ohms terminating plug.