5. Connection and Startup

5 - 56

Planning and Installation - Rev. 3 / 04.2005

Interconnection cables

HF coax cable,

length

Part number

1 m

0 782 740 100

2 m

0 782 740 600

5 m

0 782 740 300

10 m

0 782 740 200

20 m

0 782 740 400

30 m

0 782 740 700

80 m

0 782 740 500

Terminator 50 ohms

3 130 602 005

T-type connector 50 ohms

3 130 602 063

5.9

NETWORK CONFIGURATION

Mainframe, main panel and panel PC are network devices using TCP-IP protocol.

The devices are shipped with default cheapernet IP addresses; however, as more

resources are attached to the network, addresses must be changed.

Default address ranges for the devices:

IP Address (class C network)

192.168.0.1

up to

192.168.14.255

Attention:

The IP addresses of the individual devices working on the network must be

different. For mainframe and control panel, the setting can be undertaken di-

rectly on the controller board. The lowest address byte can be set in the

range from 0 to 255 with a Hex switch.

The IP address of the panel PC can be set with the Windows 95 tool “System

Control/Network” directly.

5.10

NETWORK EARTHING

The screen of the cheapernet network has to be earthed at one point to intercept

influences from outside. The network must be earthed only at one point even if the

network is extended further in order to create clear ground potential. Earthing is
made always at the mainframe. Instead of an usual 50W BNC terminator, a termina-

tor with earth screw is enclosed. The terminator has to be connected with the en-

closed earth wire to the PE terminal of the mainframe.