background image

5. Connection and Startup

5 - 46

Planning and Installation - Rev. 3 / 04.2005

Note:

The screen of the cheapernet network has to be earthed at one point to

intercept influences from outside. The network must be earthed only at one

point even if the network is extended further in order to create clear ground

potential. Earthing is made always at the mainframe. Instead of an usual 50W

BNC terminator, a terminator with earth screw is enclosed. The terminator

has to be connected with the enclosed earth wire to the PE terminal of the

mainframe.

5.5.2.6 DC In / DC Out

2

1

Item

No.:

Socket / Connector

Designation

Socket type

Connector type

Description

1

J 3 DC IN

6...8V / 300mA

9-pin D-type

female

External supply to back up the internal

stores if power failed.

2

J 3 DC OUT

max 2.5A

9-pin D-type

male

For future use