Grass Valley XtenDD DD User Manual
Page 108

5. Connection and Startup
5 - 46
Planning and Installation - Rev. 3 / 04.2005
Note:
The screen of the cheapernet network has to be earthed at one point to
intercept influences from outside. The network must be earthed only at one
point even if the network is extended further in order to create clear ground
potential. Earthing is made always at the mainframe. Instead of an usual 50W
BNC terminator, a terminator with earth screw is enclosed. The terminator
has to be connected with the enclosed earth wire to the PE terminal of the
mainframe.
5.5.2.6 DC In / DC Out
2
1
Item
No.:
Socket / Connector
Designation
Socket type
Connector type
Description
1
J 3 DC IN
6...8V / 300mA
9-pin D-type
female
External supply to back up the internal
stores if power failed.
2
J 3 DC OUT
max 2.5A
9-pin D-type
male
For future use
- LDK 5302 (24 pages)
- SFP Optical Converters (18 pages)
- 2000GEN (22 pages)
- 2011RDA (28 pages)
- 2010RDA-16 (28 pages)
- 2000NET v3.2.2 (72 pages)
- 2000NET v3.1 (68 pages)
- 2020DAC D-To-A (30 pages)
- 2000NET v4.0.0 (92 pages)
- 2020ADC A-To-D (32 pages)
- 2030RDA (36 pages)
- 2031RDA-SM (38 pages)
- 2041EDA (20 pages)
- 2040RDA (24 pages)
- 2041RDA (24 pages)
- 2042EDA (26 pages)
- 2090MDC (30 pages)
- 2040RDA-FR (52 pages)
- LDK 4021 (22 pages)
- 3DX-3901 (38 pages)
- LDK 4420 (82 pages)
- LDK 5307 (40 pages)
- Maestro Master Control Installation v.1.5.1 (455 pages)
- Maestro Master Control Installation v.1.5.1 (428 pages)
- 7600REF Installation (16 pages)
- 7600REF (84 pages)
- 8900FSS (18 pages)
- 8900GEN-SM (50 pages)
- 8900NET v.4.3.0 (108 pages)
- Safety Summary (17 pages)
- 8900NET v.4.0.0 (94 pages)
- 8906 (34 pages)
- 8911 (16 pages)
- 8900NET v.3.2.2 (78 pages)
- 8914 (18 pages)
- 8912RDA-D (20 pages)
- 8916 (26 pages)
- 8910ADA-SR (58 pages)
- 8920ADC v.2.0 (28 pages)
- 8920ADC v.2.0.1A (40 pages)
- 8920DAC (28 pages)
- 8920DMX (30 pages)
- 8920ADT (36 pages)
- 8920MUX (50 pages)
- 8921ADT (58 pages)