beautypg.com

Grass Valley XtenDD DD User Manual

Page 162

background image

7. Initial Installation

7 - 32

Planning and Installation - Rev. 3 / 04.2005

Genlock Relevant Control LEDS

at Front Side of Board:

Meaning

G6 SER_SD_REF_DETECT

G7

SER_HD_REF_DETECT

G8

SYNC_ERROR

G21

Analog input detect

“on” if serial digital reference

SDTV is detected, green

“on”, if serial digital reference

HDTV is detected, green

“on” , if selected sync input,

digital or analog, is unlocked

or not present

not used / for internal test only!

7.4.10.2 GPI Configuration

The sliding switches T12 ... T19 on the controller board RY 3490 are assigned to

the GPI inputs 1...8 (general-purpose inputs). These inputs are provided with opto-

couplers. The switches enable to match the inputs to different control concepts:

Switch in position”1” (position ”left”)

A simple connection between the two connectors activates the corresponding in-

put. This kind of control is suitable for a connection to a relay contact or to an open-

collector output.

ATTENTION!

When connecting to an open-collector output, there is no ground potential

isolation between the switcher electronics and controlling devices.

Since the circuit ground is led out of the device, the cabling has to be shielded for

this kind of control. Non-shielded cables may cause EMC and/or ESD problems!

Switch in position ”2” (position ”right”)

The optocoupler-internal LED is made available at the two connectors (including

1kOhm drop resistor). For this kind of control, a ground potential isolation is pro-

vided; the controlling device, however, has to impress a current upon the LED, i.e.

a simple contact is not suited in this case.

Due to the ground potential isolation, the cabling is less critical for this kind of con-

trol.