7. Initial Installation

7 - 37

Planning and Installation - Rev. 3 / 04.2005

Pos.

Function

Factory adjust.

G3...18

G19

G20

G21

G22

G23

G24

G25

Status LEDs

LED red 4.95V not OK, norm=off

LED green

VCC OK, norm=on

LED red VBAT FAILure (Battery defective)

LED red INIT FAILure, norm=off

LED red HOST ERROR, norm=off

LED yellow

LAN ACCess, blinking

LED red TEMP FAILure (temp too high)

G26

G27

G28

LED yellow

BSCAN (factory: BSCAN OK)

LED yellow

BSC TEST (factory: BSCAN OK)

LED yellow

ISPL (factory: PLD programming OK)

G30

G31

LED red PC POWER FAILure OK, norm=off

LED red PC RESET, norm=off

R12

Threshold for 4.95V

T2-T7

GPI configuration, see description below

T18

FLASH/EPROM

EPROM

T19

BATT ON/OFF

ON

T30

FLASH PROGR/OPERATION

OPERATION

T26

T27

The two thumbwheel switches on the front select the last byte of

the Ethernet (Hardware) Address of the device on the LAN. Per

factory preset this also forms the last byte of the IP address.

see final test

report

T28

Test program processor

T29

Reset processor

T14

DIL switches (high byte):

Sw1

0 = execute startup script

1 = do not execute startup script

Sw2

0 = start normal

1 = start verbose

Sw3

0 = normal boot

1 = boot via LAN

Sw4

1 = internal use (not used from software V2.1.1)

Sw5

not used

Sw6

not used

Sw7

not used

Sw8

not used

0

0

0

1 (0)

T15

DIL switches (low byte):

Sw1

not used

Sw2

not used

Sw3

not used

Sw4

Button lamp

0 = PCB’s Rev. 2

1 = PCB’s Rev. 1

Sw5-8 Panel type

0000 = RPD 35/32 (LX)

0001 = RPD 35/24 (L)

0