Grass Valley XtenDD DD User Manual
Page 167

7. Initial Installation
7 - 37
Planning and Installation - Rev. 3 / 04.2005
Pos.
Function
Factory adjust.
G3...18
G19
G20
G21
G22
G23
G24
G25
Status LEDs
LED red 4.95V not OK, norm=off
LED green
VCC OK, norm=on
LED red VBAT FAILure (Battery defective)
LED red INIT FAILure, norm=off
LED red HOST ERROR, norm=off
LED yellow
LAN ACCess, blinking
LED red TEMP FAILure (temp too high)
G26
G27
G28
LED yellow
BSCAN (factory: BSCAN OK)
LED yellow
BSC TEST (factory: BSCAN OK)
LED yellow
ISPL (factory: PLD programming OK)
G30
G31
LED red PC POWER FAILure OK, norm=off
LED red PC RESET, norm=off
R12
Threshold for 4.95V
T2-T7
GPI configuration, see description below
T18
FLASH/EPROM
EPROM
T19
BATT ON/OFF
ON
T30
FLASH PROGR/OPERATION
OPERATION
T26
T27
The two thumbwheel switches on the front select the last byte of
the Ethernet (Hardware) Address of the device on the LAN. Per
factory preset this also forms the last byte of the IP address.
see final test
report
T28
Test program processor
T29
Reset processor
T14
DIL switches (high byte):
Sw1
0 = execute startup script
1 = do not execute startup script
Sw2
0 = start normal
1 = start verbose
Sw3
0 = normal boot
1 = boot via LAN
Sw4
1 = internal use (not used from software V2.1.1)
Sw5
not used
Sw6
not used
Sw7
not used
Sw8
not used
0
0
0
1 (0)
T15
DIL switches (low byte):
Sw1
not used
Sw2
not used
Sw3
not used
Sw4
Button lamp
0 = PCB’s Rev. 2
1 = PCB’s Rev. 1
Sw5-8 Panel type
0000 = RPD 35/32 (LX)
0001 = RPD 35/24 (L)
0