beautypg.com

Grass Valley XtenDD DD User Manual

Page 31

background image

2. Technical Data

2 - 3

Planning and Installation - Rev. 3 / 04.2005

2.1.8

INTERFACE DATA

8+6 intern GPI, 8+6 intern GPO
GPI: Opto coupler, dry contact or active in, (8 Mainframe, 6 Panel) max. 40mA.

GPO: Silicon switches, potential free, 40V/0.3A.

D-Sub socket 50-pin, female (panel 25-pin, female) 40 V, 0.5 A

9 Serial ports (Mainframe) D-Sub sockets 9-pin, female, RS 485/422,
38.4 kbd max.

Tributary-Bus Controller mode switchable, for DVE, Edit Systems, ext DSK,

1 RS485/RS422-Serial Extension, D-Sub socket 9-pin, female
port for serial Tally & more optional Tallies: CH1 (r), CH2 (g), Preset (y),

GP I/Os- support of up to 68 ext. Tally Outputs

- support of up to 21 ext. Tally inputs

- further 40 GPI/GPO channels

5 Serial ports (Mainframe)
2x D-Sub sockets 9-pin, female, RS 232C, 38.4 kbd max,

1x D-Sub socket 15-pin, female (Multi Port) with 3x RS 232C

3 Service ports, D-Sub sockets 9-pin, female, RS 232C
(2x Mainframe, 1x Panel)

2 Modem ports, D-Sub sockets 25-pin, female, RS 232C
(1x Mainframe, 1x Panel)

LAN (mainframe), 1 BNC (remote), cheapernet,
50 ohms, 150 m, with repeater max. 2.5 km,

can be looped through with a T-type connector

LAN (control panel), 1 BNC, cheapernet,
50 ohms, 150 m, with repeater max. 2.5 km,

can be looped through with a T-type connector

LAN (panel PC), 1 BNC , cheapernet,
50 ohms, 150 m, with repeater max. 2.5 km,

can be looped through with a T-type connector

4 Serial ports (Control Panel), D-sub sockets 9-pin, female, RS485/422C
for UMDs or Aux extensions

2 Serial ports (Control Panel), 2x D-sub sockets 9-pin, female,
RS232C, 38.4 kbd

PC Communication Ports (several) VGA Port, LCD, PS/2, RS 232C