3. Installing Mainframes

3 - 6

Planning and Installation - Rev. 3 / 04.2005

3.4.2

SMALL MAINFRAME SH-1/2S BM

The ambient temperature during operation must not fall below + 5 °C or exceed

+ 40 °C (41 °F to 104 °F). Optimum operation is ensured at an ambient temperature

of 20 °C.

The mainframe is ventilated by the fan unit (8 fans) being mounted at the left side

in the mainframe. The air is sucked in at the left side of the mainframe and is ex-

hausted at the right side through the louvers. These fans serve to support air cir-

culation in the unit and to lead the heated air into the room. The power supplies in

the lower part of the carrier are cooled by two internal fans. The air is sucked in at

the front and is let out through the louvers at the rear.

In order to ensure continuous air circulation, make sure that the air slots on

the left and right side and on the rear side of the unit are not covered when

mounting the mainframe.

Air intake

Exhaust air exits from

the right of the unit

from the left side

Note:

The door is an integral part of the cooling airflow design.

For proper cooling keep the door closed during normal

operation.