Tally menu, Tally menu -28, Figure 2-16 – Grass Valley 1200 Operation Manual User Manual
Page 46: Gpi outputs menu -27, Figure 2-16. gpi outputs menu, Aux bus tally back), Selection, when set to, Soft button to the, Button to

2-28
Section 2— Startup
Figure 2-16. GPI Outputs Menu
Tally Menu
The Tally menu (Figure 2-17) displays a table listing the 16
physical signal inputs, indicating those that are high-tallied by
highlighting them.
The
AUX TALLY BACK
(Aux Bus Tally Back)
ON/OFF
selection,
when set to
ON
, allows use of a GPI to tally Aux Bus 1 whenever
the effects send fill crosspoint is tallied and Aux Bus 2 whenever
the effects send source crosspoint is tallied. This provides tally
back for an external DPM without requiring a tally back input
from the DPM. To use this feature, it must be enabled in the Tally
menu and assigned as an event to a GPI input in the GPI Inputs
menu.
The
TALLY TEST
selection allows you to test the tally output
relays. To test all of the tally outputs, set the
[TALLY TEST]
soft
button to the
ON
position; this cycles each output on for about
1/2 second. When finished testing, set the
button to
OFF
.
TALLY MENU
AUX TALLY
BACK
TALLY
TEST
PHYSICAL
INPUT
SIGNAL NAME
BLACK
BLACK
Exit
J1
VTR 1
J4
VTR 2
J6
R-VTR
J2
CHAR GEN V
J3
CHAR GEN K
J8
DPM-700 VIDEO
ON
OFF
J7
DPM-700 KEY
J9
J8
J11
J12
MATTE
J16
BARS
CAMERA 1
CAMERA 2
PAINTBOX
MATTE
STILL STORE
PHYSICAL
INPUT
SIGNAL NAME
ON
OFF