Jupiter L-S Series Control Panels Installation and Operating Manual
87
S25/S50 Control Panels
S25/S50 Control Panels
For a summary of S25/S50 functions see
Figure 32. S25 Control Panel
Figure 33. S50 Control Panel
S50
The S25 and S50 are button-per-source control panels configurable for
various combinations of destinations and levels. The buttons on the left
select sources. The eight buttons on the right select levels or destinations.
If desired, breakaways can be disabled on the CP Level Set table by setting
the Break Flag for each level to `N.'
The S50 is configured and operated same as the S25, except that buttons are
provided for 50 sources.
1 Destination / 8 Levels
If the S25/S50 is configured to control a single destination, the eight-button
cluster on the right can be used for breakaway switching of the first eight
levels of the router. An example is shown in
.
Figure 34. S25
8 Levels
Sources
Configured for 1 Destination / 8 Levels
This configuration is indicated when all eight buttons are illuminated in
low or high amber.
Note