Network Wiring
Network Wiring
The L-S series panels are connected to the CM-4000 System Controller via
Ethernet. Maximum length of a LAN (Cat5 cable) connection is 329 feet
(100 meters). The LAN must be capable of 100 Mb operation, and each
Ethernet segment (hub to panel) has a 100 meter limit. See
.
Figure 11. LAN only system connections.
LAN 1 (Cat 5 Ethernet) cable.
Max. recommended length per
segment = 100 meters (329 ft)
CM-4000
System
Controller
(AccuSwitch)
100baseT Jupiter LAN
to Jupiter
File Server
64 LAN-operated
L-S panels per CM
maximum
8536_08
IP switch
Button Labels
Most L-S series panels are supplied with “typical use” button labels already
installed. Additional buttons can be labelled in the field. Two resources are
available for labels:
•
A pre-printed/pre-cut transparency keycap label sheet is supplied with
each panel. See
Keycap Transparency Labels on page 36
•
Microsoft Word files are available for creating custom labels. For more
information, contact Grass Valley Technical Support.