Configuring Internal Test Signal Generators

The 9430 is equipped with two independent internal Test Signal Generators (TSG). These generators
are driven from the genlock source chosen by the Reference Source control on the Timing and Genlock
page.

Each TSG can be independently configured for format, frame rate, and test pattern. The TSG outputs
will always be clock-locked to the reference source. Further, they will be vertically locked and timed if
the video standard the TSG is configured for is compatible with the provided reference.

Because the Router generates the test signals internally, the TSGs are available as sources in the Router
(without consuming a physical input BNC) and can be selected to any output destination. Source
names can be assigned to them in the Port Configuration menu, and their position on control panels is
assigned in the Profiles menu.

Test Signal Generator Configuration

There are two sets of configuration controls, one for each TSG. These configurations are independent,
allowing the two generators to operate in different formats – and even at different frame rates. To
configure them to the same standard, and to set them to matching timing (relative to the genlock
reference), make the same settings for Standard, Vertical Timing, and Horizontal Timing.

Internal

Precision

Reference

Slate/

Cyclops

Test Sig

Gen 2

Slate/

Cyclops

Test Sig

Gen 1

Audio

Embed

Audio

Embed

Tone

Gen

Genlock

Master

Reference

Input