beautypg.com

Router control connections, Rs-232 and 100mb ethernet interface adaptor cable – Ensemble Designs 9430 Flexible Matrix Router for 3G / HD / SD / ASI User Manual

Page 32

background image

www.ensembledesigns.com

Page 32

Avenue 9430 Flexible Matrix Router

Installation, Configuration and Operations Guide

Router Control Connections

Although the Avenue Frame system is equipped with both RS-232 and Ethernet interfaces, the 9430
has its own dedicated control connections. The communication bandwidth needed to support the live
video thumbnails and the expectation on the part of third-party control systems (automation, event
control) for a dedicated control port require this.

RS-232 and 100Mb Ethernet Interface Adaptor Cable

The connection to both the RS-232 and 100Mb Ethernet interfaces on the 9430 are accomplished
through an adaptor cable (part number 23700040) which connects to the HD-15 connector specific to
the slot where the 9430 is installed. This adaptor is included with the 9430 module. It is configured as a
“Y” cable with a separate leg for the 9-pin D-Sub RS-232 and RJ-45 Ethernet connectors. If only one of
these interfaces is required, it is acceptable (though irreversible) to cut off the unwanted leg.

The Ethernet port should be connected with CAT5 or CAT6 cabling to a network Ethernet router or
switch to make it accessible to computers on the network. This port can also be directly connected to
a computer or to a Router Control Panel (5830). The Ethernet port will auto-sense cable direction, so a
cross-over cable is not needed.

The RS-232 port will operate from 1,200 to 115,200 baud.

The configuration of these interfaces and the selection of serial protocol are described in Chapter 6:
External Control on page 96.

Rear BNC connectors and the HD-15 connector

on the 9430

Adaptor “Y” cable (part number 23700040)

for connecting the 9430 to RS-232 and 100Mb

Ethernet interfaces

This manual is related to the following products: