beautypg.com

Gpi control – Ensemble Designs 9430 Flexible Matrix Router for 3G / HD / SD / ASI User Manual

Page 38

background image

www.ensembledesigns.com

Page 38

Avenue 9430 Flexible Matrix Router

Installation, Configuration and Operations Guide

GPI Control

The Router Control Panel is equipped with 8 GPI (General Purpose Interface) inputs. These provide a
simple, wire-per-function interface for applications such as:

Master Control Fault “Panic” Button

Monitor Follow in Camera Shading

Crosspoint selection from relay contact closure

Connection to the GPI Inputs is made through the female 9-pin D-Sub connector on the rear of the
Router Control Panel.

The pinout of this connector is organized as follows:

Pin #

Function

1 - 8

GPI Inputs 1 through 8

9

Ground

A GPI function is activated by making a momentary connection between the GPI pin and ground. This
can be done with a switch, a relay, or an open-collector driver. The GPI input is internally pulled high,
the external control must sink 1 mA.

Functions are assigned to the GPIs through the Control Profile that has been assigned to the panel.

For more information about Profiles, see Creating and Editing Profiles on page 59.

This manual is related to the following products: