Westermo PMI-110-F2G User Manual
Page 66

The max budget is different between 802.3af, 802,3at and forced
of 802.3af powering mode is 15.4.
at powering mode is 30
mode is 30.
powering mode.
The max budget
The max budget of 802.3
The max budget of force powering
Examples
Set the max value of power consu
mode.
mption to 12 W with manual
udget 12
Switch(config‐if)# poe b
Syntax
poe budget warning <0‐100>
Parameters
<0‐100> 0 is disable, valid range is 1 to 100 percentage
Command Mode
Interface mode
Description
Set the warning water level of port budget.
Examples
Set the warning water level to 60%
Switch(config‐if)# poe budget warning 60
Syntax
poe priority critical/high/low
Parameters
Critical : Hightest priority level
High : High priority level
Low : Low priority level
Command Mode
Interface mode
Description
Set the powering priority. The port with higher priority will have
ery power under limited power situation.
the privilege to deliv
Examples
Set the priority to critical
Switch(config‐if)# poe priority critical
Syntax
poe schedule weekday hour
Parameters
onday, …, 6=Saturday)
rmat a,b,c‐d
Weekday : Valid range 0‐6 (0=S
Hour : Valid range 0‐23, Valid fo
unday, 1=M
Command Mode
Interface mode
Description
interface.
Add a day schedule to an
Examples
Add a schedule which enables PoE function at hour 1, 3, 5 and 10
to 23 on Sunday.
Switch(config‐if)# poe schedule 0 1,3,5,10‐23
Syntax
no poe schedule weekday
Parameters
1=Monday, …, 6=Saturday)
Weekday : Valid range 0‐6 (0=Sunday,
Command Mode
Interface mode
Description
Remove a day schedule
Examples
Remove the Sunday schedule.
Switch(config‐if)# no poe schedule 0
Syntax
poe budget DC1/DC2 [POWER] ; system command for
PMI‐110‐F2G is 120Watts under 70C operating temperature.
Parameters
POWER : 0~200
Command Mode
Configuration mode
Description
Set the power budget of DC1
Examples
Set the power bu
Switch(config)# poe
dget of DC1 to 200W
budget DC1 200w
Syntax
poe budget warning <0‐100>
Parameters
is 1 to 100 percentage
<0‐100> 0 is disable, valid range
Command Mode
Configuration mode
62