VCM-X / RNE STATUS

VCM-X / RNE Operator Interface SD

55

VCM-X / RNE Status Screen Index

Status Screen #1

HVAC Mode

Status Screen #2

Cooling/Heating/Economizer Status

Status Screen #3

Mode Enable Temperature and

Cooling

and

Heating

Setpoints

Status Screen #4

Current SAT Temperature and Setpoint

Status Screen #5

Space Temperature, Return Air

Temperature,

and

Slide

Adjust

Status Screen #6

VCM-X Leaving Water Temperature A

OR

RNE

Leaving

Water

Temperature

1

Status Screen #7

VCM-X Leaving Water Temperature B

OR

RNE

Leaving

Water

Temperature

2

Status Screen #8

Coil Temperature or Lowest Coil and

Coil

Temperature

Setpoint

Status Screen #9

Current Outdoor Air Temperature and

Current

Outdoor

Air

Relative

Humidity

Status Screen #10

Current Calculated Outdoor Air

Dewpoint

and

Current

Dewpoint

Temperature

Status Screen #11

Current Indoor RH Percentage and

Current

Indoor

RH

Setpoint

Percentage

Status Screen #12

Current Static Pressure and Output

Percentage

Status Screen #13

Economizer Percentage, Outdoor Air

Wetbulb/Drybulb,

and

Current

CO

2

Level

Status Screen #14

Title 24 Economizer Feedback Status

Status Screen #15

Outdoor Air CFM & Outdoor Air

Setpoint

Status Screen #16

Supply Air CFM & Return Air CFM

Status Screen #17

Current Building Pressure & Output

Percentage

Status Screen #18

MODGAS Output Percentage &

MHGRV

Output

Percentage

VCM-X / RNE Status Screen Index

Status Screen #19

Current Modulating Heating & Cooling

Output

Signal

Percentage

Status Screen #20

VCM-X Coil Temperatures for Full

Digital,Water

Source

Heat

Pump

or

Dual

Digital

OR

RNE

Coil

Temperatures

for

Full

Digital

or

Water

Source

Heat

Pump

Status Screen #21

VCM-X Coil Temperatures for Full

Digital,Water

Source

Heat

Pump

or

Dual

Digital

OR

RNE

Coil

Temperatures

for

Full

Digital

or

Water

Source

Heat

Pump

Status Screen #22

VCM-X Full Digital Module Signal,

Water

Source

Heat

Pump

Module

Signal

or

Dual

Digital

Module

Signal

OR RNE Full Digital Module Signal or

Water

Source

Heat

Pump

Module

Signal

Status Screen #23

Current Head Pressure Cooling or

Reheat

Setpoint

Status Screen #24

Head Pressure and Condenser Fan #1

Speed

Status Screen #25

Head Pressure and Condenser Fan #2

Speed

Status Screen #26

Head Pressure and Condenser Fan #3

Speed

Status Screen #27

Head Pressure and Condenser Fan #4

Speed

Status Screen #28

Current Preheat-X Leaving Air

Temperature

and

Entering

Air

Temperature

Status Screen #29

Current Preheat-X Modulating Position

and

Active

Stages

Status Screen #30

Return Air Bypass Damper Signal &

Bypass

Damper

Signal

Status Screens #31-51 Supply Fan and Other Relays

Alarm Status Screems Alarm Conditions