General information about commands, Command execution i/o signals, Dedicated to standard mode – Denso RC5 User Manual
Page 65: 1 general, Information about commands, 1 general information about commands
45
3.5 Command Execution I/O Signals
Dedicated to Standard Mode
In standard mode the I/O commands can be executed using command execution I/O
signals. I/O commands execute the following.
⋅
Operate (start and stop) a program for each task.
⋅
Refer to or change variables from the external device.
⋅
Refer to or change inputs and outputs from the external device.
3.5.1 General Information about Commands
The table below shows the I/O commands functions.
I/O Command Functions
Command
Description of function
Program operation
⋅
Starts the program cycle (specified program).
⋅
Step-stops the program (specified program/all programs).
⋅
Immediately stops the program (specified program/all
programs).
⋅
Resets the program (specified program/all programs).
Speed setting
⋅
Sets the external speed.
⋅
Sets the external acceleration.
⋅
Sets the external deceleration.
Error number read
⋅
Outputs the error number to the system I/O area.
Type I variable write
⋅
Reads a value from the system I/O area and substitutes it for a
Type I variable.
Type I variable read
⋅
Outputs a Type I variable to the system I/O area.
Mode switching
⋅
Switches the robot operation mode.
Clear robot failure
⋅
Clears a robot failure from the external device.
Internal I/O write
⋅
Sets the state of internal inputs and outputs.
Internal I/O read
⋅
Outputs the state of internal inputs and outputs to the system I/O
area.