beautypg.com

Normal cpu (output), 6 normal, Cpu (output) – Denso RC5 User Manual

Page 52: 6 normal cpu (output)

background image

32

3.2.6 Normal CPU (Output)

(1) Function

The signal outputs to the external device that the Robot Controller CPU
(hardware) is normal.

(2) Terminal number

No.1 of connector CN10.

(3) Usage

 The signal is used to light the Robot Controller external operating panel

error indicator lamp.

‚ The signal is used when a normal CPU SIGNAL is turned OFF because

of an error and the PLC corrects it.

(4) ON conditions

The signal will be turned ON by the hardware when the Robot Controller
CPU operates normally with the power turned ON.

(5) OFF conditions

The signal will be turned OFF by the hardware when the CPU does not
operate normally.

Caution: The OFF state of this signal indicates that the Robot Controller

internal arithmetic circuit may be damaged. Therefore, ROBOT
ERROR, ERROR NUMBER, and other outputs may not be
correct.

Normal CPU Output

Normal CPU output

Power ON (CPU operating properly)

Abnormal CPU (hardware error)