4.4.5 Program Reset (Input)

(1) Function

By turning ON (short) this signal, any program can be forcibly executed
from the beginning in a step-stopped state and a suspended state.

Caution: Generally, a step-stopped or suspended program resumes

from where it stopped.

(2) Terminal number

No.24 of connector CN8.

(3) Input conditions and operation

When issued with the Program Start

 The figure below shows the input conditions and an operation timing

chart.

‚ Use the program reset signal together with a program No. select signal,

and input it before the program start signal (1 msec. or more).

ƒ Turn OFF the program reset signal after the robot starts to operate

(after a program start reset signal is output).

„ A program No. select signal is required to execute the same program

number as the suspended one from the beginning.

Input Conditions and Operation of Program Reset Signal