beautypg.com

Step stop (all tasks) (input), 7 step stop (all tasks) (input) – Denso RC5 User Manual

Page 121

background image

101

4.4.7 Step Stop (All Tasks) (Input)

(1) Function

Input this signal to step-stop the program being executed from the
external device. All tasks will be step-stopped.

(2) Terminal number

No.5 of connector CN8.

(3) Input conditions and operation

 If the status of this signal is changed from ON (shorted) to OFF (open),

the robot will stop all tasks immediately after the ongoing step is
completed, and the Robot-in-operation signal will be turned OFF.
However, External Auto mode will remain valid, and the suspended
program will be resumed by inputting a program start signal. See the
figure given below.

‚ Turning OFF (open) this signal when inputting a program start signal

makes the robot stop step by step.

ƒ Internal operation with the teach pendant is valid only when the status

of this signal is changed from ON (shorted) to OFF (open).

„ For resuming the program after a step stop, refer to Subsection 4.4.4

"Program Start (Input)".

Robot-in-operation

ON

(output)

OFF

Single-cycle operation

Robot status

Performing
remaining

Operating halfway

Step-stop

operation

Program start

ON (shorted)

signal (input)

OFF (open)

Step-stop

ON (shorted)

signal (input)

OFF (open)

Step Stop Signal