beautypg.com

Denso RC5 User Manual

Page 113

background image

93

‚ When the status of the program start signal is switched from OFF to

ON with the program step-stopped, the program will resume from the
step following the suspended step and stop at the cycle end.

Single-cycle operation

At step-stop

Robot status

Program start

ON (shorted)

signal (input)

OFF (open)

Step-stop

ON (shorted)

signal (input)

OFF (open)

Operating halfway

Performing
remaining
operation

Program Start Operation-2

Caution:

To cancel the execution of the remaining steps of a step-
stopped program and start it from the beginning, input a
program reset signal, a program No. select signal and a
program start signal at the same time. For further information,
refer to Subsection 6.4.5 "Program Reset (Input)".