124

5.2.4 Emergency Stop Circuit

The following figures show the examples of configuration and connection of
emergency stop circuit for the robot controller.

The red mushroom-shaped switch provided on the robot controller front panel, on the
teach pendant, or on the operating panel can be used as a switch for stopping the
equipment in case of emergency.

5.2.4.1

Standard type

Emergency
Stop +

Internal 24V

Robot controller

F1

Fuse (1.3A)

Fuse (1.3A)

F2

F9

Fuse (0.3A)

Internal 0V

Internal

24V

F8

Fuse (1.3A)

Emergency
Stop +

Emergency stop switch
on teach pendant

Input

Emergency stop switch
on the front panel of the
controller

Robot stop switch circuit
(prepared by customers)

Emergency stop circuit
(prepared by customers)

Teach pendant

Internal 0V

CN8

Output

CN10

CN5

CN7

(When the internal power source is used)

Emergency
Stop +

Robot controller

F9

Fuse (0.3A)

Internal

24V

F8

Fuse (1.3A)

Emergency
Stop -

Emergency stop switch
on teach pendant

Input

Emergency stop switch
on the front panel of the
controller

Robot stop switch circuit
(prepared by customers)

Emergency stop circuit
(prepared by customers)

Teach pendant

Internal 0V

CN8

Output

CN10

CN5

External 0V

External 24V

(When an external power source is used)

Emergency Stop Circuit (Standard type)