beautypg.com

Denso RC5 User Manual

Page 106

background image

86

4.3

Types and Functions of System Input Signals

(Compatible Mode)

The table below lists the system input signals to be used in compatible mode.

Types and Functions of System Input Signals to be Used in Compatible Mode

Application

Signal name

Function

Enable Auto

Enables switching to Auto mode.

Motor power ON
+ operation preparation start

Turns ON the power to the motor.

CAL execution
+ operation preparation start

Executes calibration.

SP100
+ operation preparation start

Sets the speed to 100%.

Switch Ext Mode
+ operation preparation start

Switches the mode to external mode.

Program reset
+ operation preparation start

Initializes all programs on halt. Starting a
program after initialization will execute the
program from the beginning.

Start-up

Program No. select
+ program start

Executes a specified program.

Program reset
+ program No. select
+ program start

Cancels the current program and starts
executing a specified program from the
beginning.

Program
execution

Robot stop

Stops the robot by opening signals.

Robot stop

Stops the robot by canceling signals.

Step stop

Step-stops all programs by opening signals.

Stop

Instantaneous stop

Instantaneously stops all programs by
opening signals.

Error clear

Clear robot failure
+ operation preparation start

Clears an error.

Program interrupt

Interrupt skip

Interrupts the execution of the current step
and starts the next step.

Continue start

Continue start
+ program start

Executes continue start.

Caution: Two or more signal names listed in the signal name field

indicate that they should be used in combination.