beautypg.com

Connector pin assignment in standard mode, 2 connector pin assignment in standard mode – Denso RC5 User Manual

Page 152

background image

132

6.1.2 Connector Pin Assignment in Standard Mode

(1) OUTPUT CN10: User-/System-output connector (standard mode)

CN10 Pin Assignment, in standard mode (PNP type)

View from the cable side

Terminal

number

Name

Port

number

Wire

color

Terminal

number

Name

Port

number

Wire

color

1

Normal CPU

72

Black

35

User output

106

Pink

2

Robot in operation

73

Brown

36

User output

107

Pink

3

Robot failure

74

Red

37

User output

108

Pink

4

Servo ON

75

Orange

38

User output

109

Pink

5

Robot initialization complete

76

Yellow

39

User output

110

Pink

6

Automatic mode

77

Black

40

User output

111

White

7

External mode

78

Brown

41

User output

112

White

8

Dead battery warning

79

Red

42

User output

113

White

9

Robot warning

80

Orange

43

User output

114

White

10

Continue start permitted

81

Yellow

44

User output

115

White

11

SS mode

82

Green

45

User output

116

White

12

Reserved

83

Blue

46

User output

117

White

13

Reserved

84

Violet

47

User output

118

White

14

Reserved

85

Gray

48

User output

119

White

15

Command processing complete

86

Pink

49

User output

120

White

16

Status area odd parity

87

Black

50

User output

121

Gray

17

Status area bit 0

88

Black

51

User output

122

Violet

18

Status area bit 1

89

Brown

52

User output

123

Violet

19

Status area bit 2

90

Red

53

User output

124

Violet

20

Status area bit 3

91

Orange

54

User output

125

Violet

21

Status area bit 4

92

Yellow

55

User output

126

Violet

22

Status area bit 5

93

Green

56

User output

127

Violet

23

Status area bit 6

94

Blue

57

Not used.

Violet

24

Status area bit 7

95

Gray

58

Not used.

Violet

25

Status area bit 8

96

Pink

*59

[ Power supply for Robot
stop 1 (Internal +24V) ]

Violet

26

Status area bit 9

97

Brown

*60

[ Robot stop 1 ]

Gray

27

Status area bit 10

98

Red

*61

[ Power supply for Robot
stop 2 (Internal +24V) ]

Gray

28

Status area bit 11

99

Orange

*62

[ Robot stop 2 ]

Gray

29

Status area bit 12

100

Yellow

*63

[ Emergency stop (+) ]

Gray

30

Status area bit 13

101

Green

*64

[ Emergency stop (-) ]

Gray

31

Status area bit 14

102

Blue

65

Emergency stop 2 (+)

Gray

32

Status area bit 15

103

Pink

66

Emergency stop 2 (-)

Gray

33

User output

104

Black

*67

[ Deadman switch (+) ]

Blue

34

User output

105

Brown

*68

[ Deadman switch (-) ]

Blue

NOTE 1: The optional I/O cable for the above connector consists of twisted pair wires--pairs of #1 and #35,
#2 and #36, #34 and #68.
NOTE 2: The terminal number marked with ( * ) is used only for “Dual emergency stop type”.