beautypg.com

Gasboy Islander PLUS User Manual

Page 76

background image

Terminal No.

Signal Name

Functional Description

22

+12V_6_P

+12 VDC Output to Pulser – Nozzle 6

23

+12V_7_P

+12 VDC Output to Pulser – Nozzle 7

24

+12V_8_P

+12 VDC Output to Pulser – Nozzle 8

25

IN USE 1 A

Handle Up – AC In Use signal input - Nozzle 1

26

IN USE 2 A

Handle Up – AC In Use signal input - Nozzle 2

27

IN USE 3 A

Handle Up – AC In Use signal input - Nozzle 3

28

IN USE 4 A

Handle Up – AC In Use signal input - Nozzle 4

29

IN USE 5 A

Handle Up – AC In Use signal input - Nozzle 5

30

IN USE 6 A

Handle Up – AC In Use signal input - Nozzle 6

31

IN USE 7 A

Handle Up – AC In Use signal input - Nozzle 7

32

IN USE 8 A

Handle Up – AC In Use signal input - Nozzle 8

33

IN USE 1 B(-)

Handle Up – AC In Use signal Return - Nozzle 1

34

IN USE 2 B(-)

Handle Up – AC In Use signal Return - Nozzle 2

35

IN USE 3 B(-)

Handle Up – AC In Use signal Return - Nozzle 3

36

IN USE 4 B(-)

Handle Up – AC In Use signal Return - Nozzle 4

37

IN USE 5 B(-)

Handle Up – AC In Use signal Return - Nozzle 5

38

IN USE 6 B(-)

Handle Up – AC In Use signal Return - Nozzle 6

39

IN USE 7 B(-)

Handle Up – AC In Use signal Return - Nozzle 7

40

IN USE 8 B(-)

Handle Up – AC In Use signal Return - Nozzle 8

41

LINE 1

Pump control 220/110 VAC Input - Nozzle 1

42

LINE 2

Pump control 220/110 VAC Input - Nozzle 2

43

LINE 3

Pump control 220/110 VAC Input - Nozzle 3

44

LINE 4

Pump control 220/110 VAC Input - Nozzle 4

45

LINE 5

Pump control 220/110 VAC Input - Nozzle 5

46

LINE 6

Pump control 220/110 VAC Input - Nozzle 6

47

LINE 7

Pump control 220/110 VAC Input - Nozzle 7

48

LINE 8

Pump control 220/110 VAC Input - Nozzle 8

57

NEUTRAL IN (115/230v)

Neutral Connection, OrIC power input

58

LINE IN (115/230v)

Line Connection, OrIC power input

59

GROUND IN

Ground Connection, OrIC power input

9

PULSER_1

Pulser Input – Nozzle 1

Islander PLUS Manual

62

This manual is related to the following products: