Table 5-1. Islander PLUS Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

Mechanic pump does not refuel (Continued)

Pump is
authorized but
Call state is not
detected (nozzle
icon in SiteOmat
Status screen
does not display
Call state)

Faulty in-use switch
in pump

Power off the pump, using
a ohmmeter measure the
switch in on and off states

Replace pump switch in
cases where no short was
detected

Faulty connections

Check In Use cable

Check In Use terminal
block connections

Make good electrical
connection if faulty one
exists

Faulty In Use
terminal block

Replace In-use terminal
block

Faulty MPI-C board Verify that the Call red

LED is lit when nozzle is
lifted

If the red LED is not lit,
replace MPI-C board.
If the led is lit, the problem
is external to the controller

Faulty 8-Port

Replace 8-Port

Pump is
authorized, pump
motor is running,
but no fuel is
supplied

Faulty solenoid
valve

Faulty pump

Does the pump solenoid
valve produce a clicking
sound?

1. Replace valve

2. Repair pump

Payment device
(card, key, tag,
Fuel Ring) is not
accepted

Communication
fault between OrPT
and SO

1. Check LAN cable

2. Check OrPT setup

3. Check SO setup

1. Replace LAN cable, if

necessary

2. Set OrPT parameters

properly

3. Set SO parameters

properly

Communication
fault between FHO
and SO

1. Check connection path

with FHO

2. Verify that the station

is available and
synchronized with
FHO in FHO Stations
Status screen

Repair communication
between FHO and SO,
providing a reliable
communication line

Islander PLUS Manual

99