2-8. WIRING THE PERIPHERALS

2-8.1. Pump Wiring

Islander PLUS is capable of directly driving pump motors up to 3/4 HP at 115 VAC or 1-1/2 HP at
230 VAC. Additional external relay must be used if pump motor exceed this limitations. A separate
circuit breaker should be supplied for each dispenser. Wire the pump as follows:

• Wire one Mains AC cable from the UPS-MCC to the pump enclosure, intended for

the pump motor.

• For an electronic pump, wire RS485 / Current Loop / Tokheim communication cable

from the Islander PLUS to the pump head.

• Wire one 0.4" (10 mm) ground cable from the Mains ground connection to the pump

chassis.

• The communication cable shield must be connected to ground at one end-side only,

preferably at the controller installation side (see Figure 2-10).

Figure 2-10 Communications Cable Wiring

2-8.2. TLG wiring

RS-232/LAN is used for communication between the TLG and Islander PLUS. Follow these
installation requirements when installing the RS-232/LAN communications lines:

NOTE

These requirements shall be compatible with the
recommendations of the TLG manufacturer.

Distance: the following distances must be adhered to when installing the
communication lines:

o

RS-232: 1 – 50 feet (1 – 15 m) for direct connection to a TLG device.

Islander PLUS Manual