Figure 2-6 power equipment connections – Gasboy Islander PLUS User Manual
Page 52

• Mains Circuit Control Box (MCC)
• Uninterruptible Power Supply (UPS) – Online ("True") UPS
Figure 2-6 shows the requested connections of the power equipment.
Figure 2-6 Power Equipment Connections
Beside the power equipment, other components shall be connected to the power supply such as the
TLG and the dispensers.
2-7.2. Islander PLUS for 8 hoses - AC Power Supply
Setup
In Islander PLUS for 8 hoses the power supply can be fed either 110 VAC or 220 VAC. The Mains
cable is first connected to the terminal block. Between the terminal block and transformer the
system uses a Line Filter in order to attenuate conducted radio frequencies - RFI, electromagnetic
interference (EMI) - between the line and the equipment (see Figure 2-7). AC power is then
supplied to an AC/AC High to Low Transformer – 110/220 VAC to 25 VAC. The transformer
requires jumpers' setup for either 110 VAC or 220 VAC Mains input, as shown in Figure 2-8. A
settings label is also found on top of the transformer.
Islander PLUS Manual
38