Table 5-2. OrPT Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

OrPT does not accept HID card/key

OrPT display
does not respond
correctly to HID
cards/keys

Bad card/key

Replace key and test again

Faulty connection

Open the Islander PLUS
door and check the cable
which connects HID
reader to the OrPT
terminal

Make good electrical
connection if faulty one
exists

OrPT is busy in
another task

check that dsplay present
the idle message

1. Press Cancel

2. Present the card/key

while the idle message
is displayed

Faulty OrPT

Replace OrPT

OrPT displays "No communication" message

Communication
disconnected

Open Islander PLUS door
and check LAN cable
from OrPT to 5-LAN
switch

Make correct and good
connection if it was
incorrect

5-LAN switch is
dead

No power to 8-Port

Are 8-Port LEDs
lit/blinking?

1. Check power connector

to 8-Port

2. Replace 8-Port

Is 5-LAN switch LEDs
are lit/blinking?

1. Check connection of

LAN switch on 8-Port.
It should be inserted in
a socket on the 8-port
main board

2. Replace 5-LAN switch

board

OrCU problem

Faulty connection

Check power to OrCU

Verify that the white power
connector is plugged into
the OrCU POWER socket

Power supply
failure

Is power supply on?

1. Replace fuse

2. Replace power supply

Faulty OrCU

Replace OrCU

Islander PLUS Manual

104