beautypg.com

6.4. installation assembly parts, 6.5. base plate installation procedures, Table 3-1. islander plus, assembly parts – Gasboy Islander PLUS User Manual

Page 67

background image

2. Run cable conduits for each type of cables to the spot:

• One High Voltage conduit from the dispenser
• One Low Voltage conduit from the dispenser
• One Low Voltage conduit from the Office
• One High Voltage conduit from the Mains Distribution Box

3. In the installation spot, dig a hole on the ground of the following dimensions:

• Width: 11.8" (300 mm)
• Length: 11.8" (300 mm)
• Depth: 15.75" (400 mm)

4. Run the cable conduits to the hole.

5. All holes in this panel must be filled when the unit is installed.

3-6.4. Installation Assembly Parts

Table 3-1 lists the assembly parts for the installation of the Islander PLUS.

Table 3-1. Islander PLUS, Assembly Parts

Item No.

Orpak Part Number

Description

Qty

1

Islander PLUS

1

2

814906200

Bolt, ICU

4

3

815103000

Nut, M10

8

4

815300200

Washer, Flat, M10

8

5

814908400

Bottom Plate

1

6

814982200

Rosette, Islander PLUS

1

3-6.5. Base Plate Installation Procedures

Proceed as follows (see Figure 3-7):

1. Prepare the Bottom Plate (5 in Table 3-1) with four ICU bolts (2 in Table 3-1) attached to it

with M10 nuts (3 in Table 3-1). Check that the bolts protrude from the plate
by 1.4" (35 mm).

2. Insert the Bottom Plate in the hole

3. Take care that all power and communication conduits pass through the central hole in the

Bottom Plate

Islander PLUS Manual

53

This manual is related to the following products: