beautypg.com

Gasboy Islander PLUS User Manual

Page 112

background image

Table 5-1. Islander PLUS Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

Mechanic pump does not refuel (Continued)

Pump does not
supply fuel

Pump setup is
incorrect

Check pump setup:

• Pump server
• Buses
• Prices
• Pulse rate

1. Set pump parameters

2. Save and reload

3. Check again

Faulty connection to
pump

Check Control cables
from Islander PLUS to
pump

Make good electrical
connection

8-port failure

Verify that Power LED
is lit

If it is off, use a voltmeter to
check power supply to the
unit:
If power supply is OK, then
replace the 8-port board. If
power supply is faulty,
replace the power supply

Verify that Control red
LED on MPI-C board is
lit

1. Replace MPI-C board

2. Replace 8-port

Pump malfunction

Turn the Islander PLUS
bypass switch on, lift the
nozzle and check that
the pump supplies fuel

If the problem persist:

1. Check Handle-On Switch

2. Repair pump

Handle-on switch
problem

Is the In Use red LED in
MPI-C board lit when
nozzle is lifted?

1. Check In Use cable and

repair, if necessary

2. Check Terminal wires

and repair, if necessary

3. Check The In Use Switch

in the pump and repair, if
necessary

Islander PLUS Manual

98

This manual is related to the following products: