Table 5-1. Islander PLUS Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

System is down (Continued)

Doesn't accept
Key/Card/Keypad
input
No
communication

OrPT setup is
incorrect

Login into OrPT and
check communication
parameters

1. Set communication

parameters

2. Submit and check again

OrCU setup is
incorrect

Check OrCU setup:

• OrPT bus
• OrPT parameters
• OrCU Administrator

parameters

1. Set communication

parameters

2. Save and reload

3. Check again

No Magnetic
Card response

Dirty or faulty
Magnetic Card
reader

Faulty Magnetic
Cards

1. Visually check

Magnetic Card reader

2. Present several

Magnetic Cards

1. Clean Magnetic Card

reader

2. Replace Magnetic Card

reader

3. Replace OrPT

No Key response

Loose cable

Faulty key
receptacle

1. Visually check Key

receptacle

2. Insert several keys

1. Replace Key receptacle

2. Replace OrPT

Customer display
is blank

Faulty Customer
display

Faulty OrPT

Verify that customer
display board is properly
connected to OrPT
interface board

1. Replace customer

display

2. Replace OrPT

Mechanic pump does not refuel

Pump does not
supply fuel

Device is not
allowed to refuel

1. Open the pump from

SiteOmat Status
screen

2. Verify that the

vehicle/device has no
limitation in FHO
setup

Enable the device to refuel

Islander PLUS Manual