Gasboy Islander PLUS User Manual
Page 117

Table 5-2. OrPT Troubleshooting (Cont'd)
Fault
Probable Cause
Checks
Corrective Action
OrPT does not accept RFID tag (Continued)
OrPT display
does not respond
correctly to tags
OrPT is busy
performing another
task
Verify that the display
presents the idle message
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Faulty OrPT
Replace OrPT
OrPT does not accept Gasboy key
OrPT display
does not respond
correctly to keys
Bad key
Replace key and test again
Faulty connection
Open the Islander PLUS
door and check the flat
wire which connects key
reader to the OrPT
terminal
Make good electrical
connection if faulty one
exists
OrPT is busy
performing another
task
Verify that the display
presents the idle message
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Faulty OrPT
Replace OrPT
OrPT does not respond to keypad entries
Pressing the
keypad buttons
does not generate
any sound and
does not affect
the display
Dirty keyboard
Clean the keyboard
Damaged keypad
Visually check the keypad
surface for any damage
Replace keypad if any
damage is found
OrPT is busy
performing another
task
Verify that the display
presents the idle message
1. Press Cancel
2. Present the tag while
the idle message is
displayed
Faulty OrPT
Replace OrPT
Islander PLUS Manual
103