beautypg.com

Gasboy Islander PLUS User Manual

Page 114

background image

Table 5-1. Islander PLUS Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

Mechanic pump does not refuel (Continued)

Payment device
(card, key, tag,
Fuel Ring) is not
accepted

Device was not
defined/incorrectly
defined in FHO

1. Login into FHO as

Fleet manager

2. Check that the device

is defined

3. Check device

parameters

4. Check that device

rules does not limit
refueling

Define the device
parameters in FHO
properly

Device limit was
passed

Verify that the device is
within the limits of its rule

For testing only, remove
any rule associated to this
device

Device was set as
Driver

1. Login into FHO and

go Devices
Management

2. Select the specific

device and check if it
was configured as
Driver

Change the device setting
to Vehicle

Device is blocked

1. Login into FHO and

go to Devices
Management

2. Check the status of the

device in the Status
column in the Devices
grid
(blocked/unblocked)

Change device status to
Unblocked

Islander PLUS Manual

100

This manual is related to the following products: