Table 5-1. Islander PLUS Troubleshooting (Cont'd)

Fault

Probable Cause

Checks

Corrective Action

Pump is Authorized and refueling but volume remains zero

Pump is refueling
but volume
remains zero

Pulse factor is zero

Check SO pump setup

Change Pump Settings to
correct the factor for the
relevant pump

Faulty MPI-C board

Faulty pulser

Disconnect the pulser and
short the pulse-in wires to
simulate pulses

If pulses are received
during refueling, replace
pump pulser

If not, replace MPI-C board

No control on refueling

Pump is refueling
without any
control

Pump is in bypass

Verify that Islander PLUS
bypass switch is off

Turn bypass switch off, if
on

Faulty SSR

Replace the relevant SSR
unit inside the Islander
PLUS

If an external relay
is used to control
the pump/valve, it
may be stuck due to
a small current leak

Add a snubber (capacitor +
resistor) in parallel to relay
input

Islander PLUS Manual

101