3. cleaning, 3.1. general, 3.2. cleaning – Gasboy Islander PLUS User Manual
Page 125: 3.3. magnetic card reader – cleaning instructions

Table 5-4. Communication Troubleshooting (Cont'd)
Fault
Probable Cause
Checks
Corrective Action
No communication to the TLS (Continued)
"Warning" signs
displayed for all
tanks on the
SiteOmat Tank
Status screen
3. Connect to the TLS network
interface through telnet
(“telnet
XXX.XXX.XXX.XXX
9999”) and check the
configuration. Confirm
proper network settings and
serial port settings (should
be 9600, 8, None, 1, None
and D6 as connection type).
By default the port is set to
10001 – confirm similar
setting of the TLS bus in the
controller setup
5-3.
CLEANING
5-3.1. General
The Islander PLUS itself as a standalone unit should be cleaned periodically at short intervals, due
to the harsh environment of the Home Base Station where they operate.
5-3.2. Cleaning
The following instructions are valid for the OrPT front panel and the Islander PLUS pedestal.
• Clean the OrPT front plastic panel with a cloth lightly moistened with WD-40 or any other
similar lubricant.
• Clean the pedestal metallic enclosure using a damp cloth and cleaning spray.
CAUTION
DO NOT use any solvents such as thinner or
benzene.
5-3.3. Magnetic Card Reader – Cleaning Instructions
The Card Reader shall be cleaned periodically, preferably once every two (2) weeks, in order to
ensure proper operation. The cleaning purpose is to remove any dust or foreign body that may
harm the reader and consequently prevent the completion of a sale.
Proceed as follows:
Islander PLUS Manual
111