beautypg.com

Gasboy MCE300 User Manual

Page 24

background image

Configuration

03/07/03

5-3

PIN LAYOUT


Your MCE 300 can calculate and print PINs (Personal Identification Numbers) used on GASBOY
CFN and Series 1000 Systems. PINs can be printed during the P (Print data) and R (Read data)
commands. PINs can be calculated only against numeric data on the card. You cannot calculate
a PIN against A, C, E, or a field separator. If PINs are desired, the following data must be loaded.

PIN LAYOUT

The PIN layout is used to determine which card characters are used for calculation of the
PIN.


P

Calculation character. Indicates the associated card layout character is used for the PIN
calculation. Only numeric characters should be indicated for the PIN calculation. No more
than 20 characters can be designated for PIN calculation.


X

Non-calculation character. Indicates the associated card layout character is not used for the
PIN calculation.


PIN

KEY

The PIN key for your site should be loaded for proper PIN calculation.


NOTE:

PINs will not be printed for cards where a READ ERROR has occurred.