MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Ethernet-based Remote Product Management

Revision 4

6–21

Clear Events Log: Select to clear all stored events from the log.

Initialize Events Pointer: Select to reset the internal pointer to allow queries to start at the

beginning of the stored events log.

Click [Submit] to execute the choice – the window will update according to the selection made.

Alarm Mask

Use the drop-down lists to select each alarm as Fault, Alarm, or Masked for:

Low Forward RF Power (operable when the BUC is optionally configured with the Power

Monitor feature).

Converter A Not Inserted.

Converter B Not Inserted.

LNA Current Detect (operable when the BDC is optionally configured with an LNA).

External Reference Lock Detected.

PS (Power Supply 1 or 2).

Click [Change Alarm Mask] to save. If it is desired to revert back to the previously assigned

Alarm Mask settings, click [Reset] instead.