beautypg.com

Comtech EF Data MBT-5000 User Manual

Page 116

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–14

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Number of

Unread stored

Statistics

N/A

3 bytes

Query only.

Unit returns the Number of stored Statistics that remain Unread, in the form xxx.

Example: NUS=126

N/A

NUS?

NUS=xxx

Part Number

N/A

Various 1-96

bytes

Query only.

Returns the Comtech EF Data part number of the unit. This part number is the unit’s DOTCODE

at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII characters

long.

Example: <1/PNM?’cr’

>0001/PNM=MBT5003.350WRSW00’cr’’lf’

N/A

PNM?

PNM=x….x

(See Description of

Arguments)

Reboot

RBT=

1 byte

Command only.

Soft Reboot

1 = Reboot System

RBT =

RBT?

RBT*

N/A

RBT=x

(See Description of

Arguments)

Retrieve

Configuration

Status

N/A

variable length

Query only.

Used to Query the Configuration status of the unit

N/A

RCS?

RCS=x….x

(See Description of

Arguments)

Example:

Description:

<1/RCS?’cr’

>0001/RCS=’cr’

ESW=1’cr’

AFR=1’cr’

XRF=N/A’cr’’lf’

Redundancy Mode

Auto Fault Recovery

External Reference Status

Note: For XRF (External reference status):

N/A = no external reference;

05M = 5 MHz;

10M = 10 MHz.

XRF will always be N/A if the internal reference oscillator option is not installed.

Reference

Oscillator

Tuning

REF=

3 bytes

Command or Query.

Adjusts the reference oscillator tuning voltage by sending a DAC value in the form xxx, where:

xxx is a numeric value from 0 to 255.

Default value: 087

Example: <1/REF=087’cr’

>0001/REF=’cr’’lf’

Note: This command sets the DAC value, but the actual Reference Oscillator tuning voltage can

be monitored using the RMS command.

REF=

REF?

REF*

REF?

REF=xxx

(Same format as