Comtech EF Data MBT-5000 User Manual
Page 116

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–14
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Number of
Unread stored
Statistics
N/A
3 bytes
Query only.
Unit returns the Number of stored Statistics that remain Unread, in the form xxx.
Example: NUS=126
N/A
NUS?
NUS=xxx
Part Number
N/A
Various 1-96
bytes
Query only.
Returns the Comtech EF Data part number of the unit. This part number is the unit’s DOTCODE
at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII characters
long.
Example: <1/PNM?’cr’
>0001/PNM=MBT5003.350WRSW00’cr’’lf’
N/A
PNM?
PNM=x….x
(See Description of
Arguments)
Reboot
RBT=
1 byte
Command only.
Soft Reboot
1 = Reboot System
RBT =
RBT?
RBT*
N/A
RBT=x
(See Description of
Arguments)
Retrieve
Configuration
Status
N/A
variable length
Query only.
Used to Query the Configuration status of the unit
N/A
RCS?
RCS=x….x
(See Description of
Arguments)
Example:
Description:
<1/RCS?’cr’
>0001/RCS=’cr’
ESW=1’cr’
AFR=1’cr’
XRF=N/A’cr’’lf’
Redundancy Mode
Auto Fault Recovery
External Reference Status
Note: For XRF (External reference status):
N/A = no external reference;
05M = 5 MHz;
10M = 10 MHz.
XRF will always be N/A if the internal reference oscillator option is not installed.
Reference
Oscillator
Tuning
REF=
3 bytes
Command or Query.
Adjusts the reference oscillator tuning voltage by sending a DAC value in the form xxx, where:
xxx is a numeric value from 0 to 255.
Default value: 087
Example: <1/REF=087’cr’
>0001/REF=’cr’’lf’
Note: This command sets the DAC value, but the actual Reference Oscillator tuning voltage can
be monitored using the RMS command.
REF=
REF?
REF*
REF?
REF=xxx
(Same format as
Command